Square fire dampers are designed for installation in general ventilation systems. When integrated into fire partitions, they provide equivalent protective performance and features as
the partitions. The fire damper blade remains open under normal operating conditions. It is closed shut automatically in the event of a fire.

temp up
6,95kW
temp down
6,45kW

50m2
energy
A+ | A++

cards

kartice jednokratno: $400,00 kn

kartice 2-12 eata: 5700 kn/ već od 475,00 kn/mj

kartice 13-24 eata: 6000 kn/ već od 255,00 kn/mj

 

grijanje
hladenje
engrijanja
enhladenja

6,95

6,45

 A +

 A ++

narudba

Podrška korisnicima:

0800/600-100
Pon-Pet:8:00-17:00

narudba

Besplatna dostava:

Za sve narudžbe iznad 1999kn

narudba

Ovlaštena montaža:

Na području cijele Hrvatske

narudba

Povratak robe:

Moguć povrat unutar 14 dana

Dostupnost: dostupno

Kupi s proizvodom:

Instalacije Klime do 3,5KW

Instalacija Klime iznad 3,5KW

Eco Sence

Usporedi
SKU: BN_87815 Kategorije: , , Oznaka:

Rectangular fire dampers FDA2-12 (T/M) with access door

The FDA2-12 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 13501-3+A1:2010P (Fire classification of construction products and building elements).
The fire resistance was tested as per PN-EN 1366-2:2015 (Fire resistance tests for service installations — Part 2: Fire dampers). The entire manufacturing process meets the requirements of EN 15650:2010. The FDA2-12 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition).

The fire dampers are available in the nominal sizes 160×160 – 1000×500 mm. All fire dampers have a torsion spring trip (in FDA2-12-T) or a return-spring actuator coupled with a thermal trip (in FDA2-12-M). The spring-action versions can be provided with optional limit switches. The casing and optional accessories are made from galvanized steel sheet; the fire damper blade is made from silicate cement board.

Square fire dampers are designed for installation in general ventilation systems. When integrated into fire partitions, they provide equivalent protective performance and features as the partitions. The fire damper blade remains open under normal operating conditions. It is closed shut automatically in the event of a fire.

The fire dampers can be installed in the following partitions:
– concrete separating floor
– concrete wall
– solid brick wall
– cellular concrete unit wall- gypsum board wall on steel frame

DODATAN OPIS

TEHNIČKI DETALJI

DOWNLOADS & CERTIFICATES

Recenzije

Trenutno nema recenzija

Budite prvi koji će ostaviti recenziju za “FDA2-12-M – FDA2-12-T”

Vaša adresa e-pošte neće biti objavljena. Obavezna polja su označena sa * (obavezno)

Related products

hrHrvatski
× Available on SundayMondayTuesdayWednesdayThursdayFridaySaturday